Water heaters

SPC Plus

Air-source monobloc heat pump water heaters

Residential
Floor standing monobloc

Heat pump technology that allows domestic hot water production whilst maintaining optimum home comfort, a short tank charging time and high efficiency.


SPC Plus consists of 200 and 250-litre floor standing models with or without additional exchanger, suitable for applications demanding high volumes of domestic hot water at temperatures up to 65°C, minimum energy consumption and eco-friendly R290 gas (GWP= 3, tCO2eq =0).

Characteristics


  • Models: 200, 250 liters with/without additional exchanger
  • Domestic hot water production up to 65°C
  • Operates with external air from -7 °C to +42 °C
  • R290 refrigerant gas (low GWP = 3)
  • Electrical back up 1,8 kW
  • Reduced electric consumption: only 450 W
  • Model with solar or boiler system integration (SPC 200 S Plus and SPC 250 S Plus)
  • Compact dimensions, height less than 1800 mm
  • Connection for PV integration
  • Easy-to-read display
  • Schedule management and consumption monitoring
  • Sanitary recirculation option (SPC 200 S Plus and SPC 250 S Plus)
  • Anti-legionella function
  • Electrical-pulse titanium anode

Features

Digital Ready

It can be connected to BaxiMAGO, the WI-FI smart modulating thermostat, and Baxi service App. You can have your boiler always under control

    Smart Grid

    It matches the supply and demand of electricity in real time, saving money on the energy bill

      65°C

      This product can produce hot water up to 65°C, without any other accessories required (such as immersion resistance)

        R290

        R290 is a gas featuring low GWP (3) and zero ODP, meaning it has a limited impact on the environment, electricity consumption and costs

          Domestic hot water

          This product allows the DHW production

            PV connection

            The connection for PV integration allows to exploit the energy from renewable sources, with further savings and overall system efficiency
              Show More
              Show Less

              Technical Specification 

              MODELSSPC 200 PlusSPC 200 S PlusSPC 250 PlusSPC 250 S Plus
              ErP data
              Load profileLLXLXL
              Energy efficiency for DHW ŋwh (3)%128%130%143%135%
              Rated heat output (1)kW1,351,341,321,3
              Absorbed electrical power (1)kW0,440,430,380,4
              COP (1)3,093,153,483,28
              Rated heat output (2)kW1,461,481,451,41
              Absorbed electrical power (2)kW0,450,440,40,4
              COP (2)3,253,333,633,54
              Performance
              Electrical back-up outputkW1,81,81,81,8
              Exchanger surface-0,93-0,93
              Loading time (1)6h 33m6h 29m8h 56m8h 37m
              Loading time - BOOST MODE (1)3h 02m3h 57m2h 57m3h 49m
              Heat losseskWh/24h1,010,971,231,19
              Maximum working pressurebar10101010
              Air flow rate (1)m³/h380380380380
              Available air pressurePa50505050
              Maximum DHW temperature *°C65656565
              40 °C mixing water volumel254338249320
              Min/max outdoor temperature (with ducting)°C-7/+42-7/+42-7/+42-7/+42
              Dimension
              Storage volumel196188251243
              Air duct diametermm160160160160
              Maximum length of the air duct (inlet and outlet)m20202020
              Miminum volume of the installation room (with ducting)m³/h10101010
              Miminum volume of the installation room (without ducting)m³/h17171717
              Refrigerant fluidR290R290R290R290
              Refrigerant fluid R513A / Equivalent CO2kg - tCO2e
              Refrigerant fluid R290 / Equivalent CO2kg - tCO2e0000
              Sound power, LwadB(A)49494949
              Power supplyV/Ph/Hz230/1/50230/1/50230/1/50230/1/50
              Dimensions (h x d)mm1528 x 6671528 x 6671760 x 6671760 x 667
              Empty weightkg8810299113

              * Maximum DHW temperature with heat pump only. Maximum water temperature with electric resistance = 75 °C.

              (1) According to EN 16147: air temperature = 7 °C, water inlet temperature = 10 °C, DHW temperature = 55 °C

              (2) According to EN 16147: air temperature = 14 °C, water inlet temperature = 10 °C, DHW temperature = 55 °C

              (3) Average climatic conditions

              Download Area

              Energy label

              Energy label

              Product Documentation

              No documentation available.

              Get more details and information about Baxi products

              Related Products

              Banner-becomedealer_2400x1440

              Become a partner

              We believe we are stronger together:

              Join Baxi in delivering innovative heating and cooling systems.

              Get in touch with our International team and discover all the opportunities